Electrical connection
Electrical connection AUS
Electrical connection of the appliance
should be undertaken by a suitably
competent person in strict accordance
with national and local safety regula-
tions.
For extra safety it is advisable to install
a residual current device (RCD), with a
trip current of 30 mA.
The appliances are supplied with a
mains cable for connection to single
phase 240 V, 50 Hz supply. The plug
rating and rated load are given on the
data plate.
Connection should be made by a
switched socket. The On-Off switch
should be easily accessible after the
appliance has been built-in.
Electrical connection NZ
The appliances are supplied with a
mains cable for connection to single
phase 230 V, 50 Hz supply. The plug
rating and rated load are given on the
data plate.
Important:
The wires in the mains lead are col-
oured in accordance with the following
code:
Green/yellow = earth
Blue = neutral
Brown = live
As the colours of the wires in the mains
lead of this appliance may not corre-
spond with the coloured markings ident-
ifying the terminals in your plug, pro-
ceed as follows:
The wire which is coloured green and
yellow must be connected to the termi-
nal in the plug which is marked with the
letter E or by the earth symbol z or col-
oured green or green and yellow.
The wire which is coloured blue must
be connected to the terminal which is
marked with the letter N or coloured
black.
The wire which is coloured brown must
be connected to the terminal which is
marked with the letter A or coloured red.
WARNING
THIS APPLIANCE MUST BE
EARTHED.
Technical data AUS (NZ)
Total connected load. . . . . . . . . . . 25 W
Electrical connection:
. . . . . . . . . . . . . . 50 Hz, 240 V (230 V)
Plug rating . . . . . . . . . . . . . . . . . . . 10 A
Connection cable . . . . . . . . . . . 1.10 m
If the connection cable needs replac-
ing, only use cable with at least
3 x 1 mm
2
.
@ä
Electrical connection
19