This appliance shall be installed in
accordance with these instructions,
local gas fitting regulations, munici-
pal building codes, electrical wiring
regulations, the AGA Installation
Code for Gas Burning Appliances
and Equipment, AGA Installation
Code for Gas Pipe Sizing Details
and any other statuory regulations.
Data plate details
The data plate is located beneath the
hotplate. Refer to the User’s Instruction-
s for details for removing the hotplate.
Check that the data plate shows the ap-
pliance is suitable for the available gas
supply.
Installation
Before installing the appliance,
check that the location provides the
required clearances from combus-
tible materials and if necessary pro-
vide protection to adjacent surfaces
as required by regulations. Make pro-
vision for the gas supply to be con-
nected in the position shown in the
diagram.
Cut the opening in the bench to the
dimensions shown in the diagram.
Make sure that there is a 240 V
(230 V) AC switch power outlet ac-
cessible within 0.9 m of the ap-
pliance, for the connection of the
spark ignition system.
Remove the hotplate from the case
(See Service or User’s Instructions).
Install the case assembly into the cut-
out and attach it with the screws pro-
vided.
The gas connection to the regulator
is
1
/
2
" BSP female thread for NG. The
regulator should be held by a span-
ner on the flats provided when mak-
ing the joints. Check for leaks using
a soap solution and brush around all
joints and connections.
Pressure Test Point. This is provided
on the gas regulator (supplied for
natural gas, TG and TLP). Loosen
the screw in the test point until it is
free in its housing. The screw is re-
tained in this position. Connect the
hose from the pressure gauge.
Reassemble one of the large bur-
ners, turn on the gas and manually
light the burners. Gas pressure
should be as shown on the data
plate:
Natural gas . . . . . . . . . . . . . . 1.0 kPa
LPG (Propane . . . . . . . . . . )2.75 kPa
LPG (Propane/Butane) . . . . 2.75 kPa
Disconnect gauge and screw in the
test point screw.
Re-assemble hotplate. Plug in the
power cable to a 240 V (230 V) outlet
and turn on the burners. The burner
ignites by turning and pressing the
knob. Sparking should cease as
soon as knob released: Check the
flame for correct combustion. Aera-
tion adjustment is available at the
end of the burner. See under conver-
sion to alternative types of gas.