Miele KM 81-2 Cooktop User Manual


 
Gas connection
Pressure regulator
A pressure regulator convertible to Natural
and LP Gas (Liquefied Petroleum) is
included with the appliance.
Conversion is carried out by inverting
the regulator cap marked "NAT"/"LP". If
"NAT" is visible then the regulator is set
for Natural gas and if "LP" is visible then
it is set for Liquefied Petroleum Gas.
Nominal rating for all types of gas
(USA/CDN)
Maximum output . 4.25 kW 14500 Btu/h
Minimum output . . . . . 0.2 kW 680 Btu/h
For USA only
The gas connection must be made
in accordance with local codes, or
in absence of local codes, with the
National Fuel Gas Code,
ANSI Z 223.1.
Gas Pressures for USA:
Max. Supply Pressure: 1/2 PSI
Manifold pressure:
– Natural gas 4" water column
– Propane gas 10" water column
Min. Supply Pressure:
– Natural gas 5" water column
– Propane gas 11" water column
For CDN only
The gas connection must be made
in accordance with local codes, or
in absence of local codes, with the
current CAN/CGA B 149.1 and .2
Inst.
Gas Pressures for CDN
Manifold pressure:
– Natural gas 4" water column
– Propane gas 10" water column
Min. Supply Pressure:
– Natural gas 5" water column
– Propane gas 11" water column
Gas connection
21