]ö
Instructions for building-in
Place the seal provided f under the
edge of the cooktop.
b Appliance
c Tensioning screw
d Clamp
e
Countertop
f Seal
Turn the tensioning screws c in a -
clockwise direction
b until a resist-
ance is felt, then turn the clamp to
the left.
Place the appliance in position, turn
the clamps and tighten the tension-
ing screws until the clamps just
touch the countertop
e. Do not over-
tighten.
Connect the appliance to the electri-
cal supply.
When building-in several Combiset
units, a stainless steel spacer bar (V 98
edge connector) must be installed be-
tween each unit. It is supplied with its
own installation instructions.
loosen
tighten
Depth
in
inch
Width *
(= Dimen-
sion B)
in inch
2 zone Combiset
1 Combiset
2 Combisets
3 Combisets
4 Combisets
5 Combisets
19-5/16"
19-5/16"
19-5/16"
19-5/16"
19-5/16"
10-7/16"
22"
33-1/2"
45-1/32"
56-9/16"
4 zone Combiset
1 Combiset
2 Combisets
3 Combisets
19-5/16"
19-5/16"
19-5/16"
22"
45"
68"
Combination
One 2 zone
+ one 4 zone
Two 2 zone
+ one 4 zone
Three 2 zone
+ one 4 zone
One 2 zone
+ two 4 zone
Two 2 zone
+ two 4 zone
19-5/16"
19-5/16"
19-5/16"
19-5/16"
19-5/16"
33-1/2"
45"
56-9/16"
56-1/2"
68-1/16"
Extractor (e.g. DA 8-2)
For building in between two appliances:
- Dimension B increases by 3 9/16".
For building in at the end of a combination:
- Dimension B increases by 3 7/8".
* Width includes provision for V 98 spacer bar
.
]ö
Instructions for building-in
27