@ä
Conversion to alternative types of gas
Replacing the small jet for the lowest
flame setting
Remove screw
d
from fitting
c
using an 8 mm spanner and a
12 mm spanner to counterhold.
Then remove the screw fitting c
from b using a 12 mm spanner and
a second 12 mm spanner to counter-
hold.
Replace the restrictor
e
contained
in section
b with the correct restric-
tor from the table of jets.
Turn the air sleeve f to adjust the
two air vents
g
to the opening
illustrated (2 mm).
Assemble removed parts in reverse
order and check for leaks by opera-
ting the wok burner without the cook-
top cover in place (ignite the flame
using a match).
Checking the first intake of air
b Fastening screw
c Air sleeve
Gap X must be 13 mm for both
natural and liquid gas.
If this is not the case, loosen the secur-
ing screw, re-position the air jet and
then tighten the securing screw.
Re-assemble the cooktop in the
reverse order.
Important note:
When reassembling, it is important
to ensure that the profile
b of the
control panel should grip the appro-
priate moulding
c on the lower pro-
tective casing.
@ä
Conversion to alternative types of gas
39