Mitsubishi Electronics A0567659 Blender User Manual


 
Gravimetric Batch Blenders w/ Mitsubishi Control Chapter 8: Addendum 95
Alarm Setup
This screen allows the user to configure the feeder type for each feeder; configure whether a
feeder will retry during the metering of a batch, and enable or disable the “Out of Material”
alarm for any feeder. If a hopper is set to “No Retry” then the blender will continue to meter
the rest of the batch even if this hopper runs out of material. No “Out of Material” alarm will
be given regardless of how the alarm is configured unless the user has purchased and wired in
the low level proximity switches in each hopper. To configure each hopper, perform the
following steps:
1. Select a feeder by touching the “Select Feeder” box.
2. The current settings for that hopper will be shown.
3. Make the necessary adjustments and select a new feeder to configure if desired.
4. Hit “Done” to exit.
Alarm Log
This screen shows the last 100 stored alarms. The log can be viewed, printed and cleared.
Select a Feeder to
Configure
Change the Alarm
Silence Delay
Enable or Disable
Retries
Enable or Disable
Alarms
Go back to Setup
Directory
Clear Alarm
Log
Print Alarm
Log
Alarm Log
Go back to
Setup
Directory
Scroll Through
Alarm Log