Taylor 300 Freezer User Manual


 
6
Models 336, 338 & 339Safety
130318
S DO NOT allow untrained personnel to
operate this machine.
S DO NOT operate the freezer unless all
service panels and access doors are
restrained with screws.
S DO NOT remove any internal operating
parts (examples: freezer door, beater,
scraper blades, etc.) unless all control
switches are in the OFF position.
Failure to follow these instructions may result in severe
personal injury to fingers or hands from hazardous
moving parts.
This unit has many sharp edges that can
cause severe injuries.
S DO NOT put objects or fingers in the door
spout. This may contaminate the product
and cause severe personal injury from blade
contact.
S USE EXTREME CAUTION when removing
the beater asssembly. The scraper blades
are very sharp.
Access to the service area of the unit is
restricted to persons having knowledge and practical
experience with the appliance, in particular as far as
safety and hygiene are concerned.
This freezer must be placed on a level
surface. Failure to comply may result in personal injury
or equipment damage.
Cleaning and sanitizing schedules are
governed by your state or local regulatory agencies
and must be followed accordingly. Please refer to the
cleaning section of this manual for the proper
procedure to clean this unit.
This machine is designed to maintain product
temperature under 41_F(5_C). Any product being
added to this m achine must be below 41_F(5_C).
Failure to follow this instruction may result in health
hazards and poor freezer performance.
DO NOT obstruct air intake and discharge openings:
3” (76 mm) minimum air space on sides and rear, and
7--1/2” (191 mm) on the bottom. The Model 338
requires 4--1/4” (108 mm) on the bottom.
Failure to follow this instruction may cause poor
freezer performance and damage to the machine.
For Indoor Use Only: This unit is designed to operate
indoors, under normal ambient temperatures of 70_ -
75_F(21_ -24_C). The freezer has successfully
performed in high ambient temperatures of
104_(40_C) at reduced capacities.
DO NOT run the machine without product. Failure to
follow this instruction can result in damage to the
machine.
NOISE LEVEL: Airborne noise emission does not
exceed 78 dB(A) when measured at a distance of 1.0
meter from the surface of the machine and at a height
of 1.6 meters from the floor .