26
Models 336, 338 & 339Important: Operator Checklist
j 7. If y our machine i s equipped with a n auxiliary
refrigeration system, check the auxiliary
condenser for accumulation of dirt and lint. Dirty
condensers will reduce the refrigeration
capacity of the mix hopper. Condensers must
be cleaned monthly with a soft brush. Never
use screwdrivers or other metal p robes to clean
between the fins.
Caution: Always disconnect
electrical power prior to cleaning the
condenser.
j 8. If your machine is water cooled, check the water
lines for kinks or leaks. Kinks can occur when
the machine is moved back and forth for
cleaning or maintenance purposes.
Deteriorated or cracked water lines should be
replaced only by an authorized Ta ylor
distributor.
Winter Storage
If the place of business is to b e closed during the winter
months, it is important to protect the freezer by
following certain precautions, particularly if the
building is subject to freezing conditions.
Disconnect the freezer from the main power source to
prevent possible electrical damage.
On water cooled freezers, disconnect the water
supply. Relieve pressure on the spring in the water
valve. Use air pressure on the outlet side to blow out
any water remaining in the condenser. This is
extremely important. Failure to follow this procedure
may cause severe and costly damage to the
refrigeration system.
Your local Taylor Dis tributor can perform this winter
storage service for you.
Wrap detachable parts of the freezer such as beater ,
blades, drive shaft, and freezer door, and place them
in a p rotected dry place. Rubber trim parts and gas kets
can be protected by wrapping them with
moisture--proof paper. All parts should be thoroughly
cleaned of dried mix or lubrication which attract mice
and other vermin.