Models 8752 & 8756 with Horizon® Pump Important: To the Operator
Auto
When the AUTO key is pressed, the light comes on
indicating the main refrigeration system has been
activated. In the AUTO mode, the WASH or STANDBY
key functions are automatically cancelled. The MIX
REF function is automatically locked in to maintain the
mix in the cabinet and the PUMP function is locked in
to allow mix pump operation as required.
Pump
When the PUMP key is pressed, the light comes on
indicating that the mix pum p will operate.
Note: An indicating light and an audible tone will
sound whenever a mode of operation has been
pressed. To cancel any function, press the key again
and the light and mode of operation will shut off.
Adjustable Draw Handle
These units feature an adjustable draw handle to
provide the best portion control, giving a better,
consistent quality to your product and controlling
costs. The draw handle should be adjusted to provide
a flow rate of 5 to 7--1/2 oz. of product by weight per
10 seconds. To increase the flow rate, turn the screw
counterclockwise.Todecrease the flow rate, turn
the screw clockwise.
IMPORTANT! When dispensing product, pull only
one draw handle at a time.
Air Flow Adjustment
Adjust air flow prior to priming the unit with mix.
Step 1
Open the p rime plug.
Step 2
Make sure the suction line is open to air flow and is not
inserted in liquid.
Step 3
Press the PUMP key.
Step 4
Adjust the air flow to the desired setting. The flow rate
is factory set at 1.0 -- 1.4.
Figure 8
Step 5
Press the PUMP key to cancel operation.
Step 6
Prime the unit according to the oper ating instructions.
Make sure the mix has stopped flowing from the purge
hole before c losing the p rime plug.