34
Models 8752 & 8756 with Horizon® PumpOperating Procedures
Step 7
Return to the freezer with a small amount of cleaning
solution. With the black bristle brush, brush clean the
rear shell bearing(s) at the back of the freezing
cylinder(s).
Figure 64
Step 8
Using the long, flexible brush and the cleaning
solution, clean the mix inlet tube(s) located in the mix
cabinet. Thoroughly clean the tube(s) all the way up to
the freezing cylinder. This area needs special attention
because bacteria and milkstone can build up here.
Figure 65
IMPORTANT:
S DO NOT insert a brush into the pump
tube.
S DO NOT remove the pump tube when
cleaning the unit.
Note: The pump tube is located inside of the
Horizon® pum p. ( See illustration on page 13.)
Step 9
Remove the rear drip pan from the side panel and take
it to the sink for cleaning.
Note: If the rear drip pan is filled with an excessive
amount of mix, refer to the Troubleshooting Guide.
Step 10
Thoroughly b rush c lean all disassembled parts in the
cleaning solution, making sure all lubricant and mixfilm
is removed. Take particular care t o brush clean the
draw valve core(s) in the freezer door. Place all the
cleaned parts on a clean dry surface to air dry
overnight.
Step 11
Wipe clean all exterior surfaces of the freezer and the
mix cabinet.