Listed below are the available parameters in the order they appear, using the down arrow key on the
controller. You can use either the up or down arrow keys to scroll through the options.
Thermostat Set Point High* Defrost Lockout 2
Thermostat Set Point Low Defrost Lockout 3
Temperature Scale Defrost Lockout 4
Time (24-hour clock) Room Temperature Offset
Date (month - day - year) Evaporator Coil Sensor Temperature
Daylight Savings Dewpoint Compensation Factor
(n/a on G-Series models)
Start Manual Defrost Cabinet Air Temperature
Defrost Lockout 1
VII. g - ADJUSTING THE THERMOSTAT SET POINT HIGH:
This parameter sets the high point of the desired cabinet temperature range. Typically, freezers will
range from -3° F to 0° F (-19° C to -18° C) and refrigerators will range from 36° F to 40° F (2° C to 4° C)
for this parameter setting. This parameter is preset at the factory and does not have to be adjusted
unless the customer chooses to do so. Note: Set Point Low and Set Point High cannot be set to the
same temperature. There will be at least 1-2 degree difference between the two settings.
Follow the instructions to enter the customer access code on page 8. When the control
display reads Thermostat Set Point High. Press the set button .
Use the arrow keys to adjust the temperature to your desired setting.
When the display shows the temperature you want press the set button .
The display will then read Thermostat Set Point High.
You can use the up or down arrow keys to scroll to the next parameter
or wait 30 seconds for the control to return to normal operation.
-9-
VII. f - CUSTOMER SERVICE PARAMETERS:
VII. MICROPROCESSOR CONTROL (continued)
SET