-15-
VII. MICROPROCESSOR CONTROL (continued)
VII. o - ADJUSTING THE ROOM TEMPERATURE OFFSET:
The room temperature offset parameter allows a service technician or end user the ability to have the
display show a temperature that is within three degrees of the actual temperature being read by the
cabinet air sensor. This allows for continuity of reading between different temperature reading devices.
(i.e.: thermistor Vs thermocouple Vs handheld thermometer) This parameter is preset at the factory to
“0” or no offset.
Follow the instructions to enter the customer access code on page 8. When the control displays
Thermostat Set High, press the down arrow key until the control display reads
Room Temperature Offset. Press the set button . Use the arrow keys to adjust the
offset to your desired setting. When the display shows the offset you want press the set button .
The display will then read Room Temperature Offset. You can use the up or down arrow
keys to scroll to the next parameter or wait 30 seconds for the control to return to normal
operation.
VII. p - VIEWING SENSOR TEMPERATURES:
These parameters allow a service technician or customer to view the temperature of all sensors
within the unit. The temperatures cannot be adjusted.
Follow the instructions to enter the customer access code on page 8. When the control displays
Thermostat Set Point High , press the DOWN arrow key unit the display reads
Evaporator Coil Sensor or Cabinet Air or press the SET button . The display
will read Thermostat Set Point High .
Press the UP or DOWN arrow keys to scroll through the parameters or wait 30 seconds
for the control to return to normal operation.
SET
SET
SET