Traulsen G-Series Refrigerator User Manual


 
COIL SENSOR*
337-60071-02
(freezer models only)
CABINET SENSOR*
337-60069-02
REFRIGERATOR
-7-
VII. MICROPROCESSOR CONTROL (continued)
LED For
° F
LED For °C
3-Digit (red)
LED Display
Defrost Icon
With LED
VII. b - CONTROL PANEL:
VII. c - PARTS ASSEMBLY:
*= Can be ordered separately
**=Requires unit Model No. & S/N to place order.
VII. a - MICROPROCESSOR CONTROL FEATURES (contd):
Water Resistant Housing
The digital controller is water resistant not only from the face of the control, but also from the rear of the housing.
Parameter/Service Levels
See Customer/Service Parameters on Page 8 - 9.
Defrost Lockouts - See Setting Defrost Lockouts on page 14
Customers can set up to 4 different defrost lockout periods. The lockout prevents the unit from going into a defrost cycle
during peak kitchen use. Note: The 24-hour clock must be set for this feature to operate correctly.
°F °C
FREEZER
SET