Vulcan-Hart ML-136058 Electric Steamer User Manual


 
MODEL C24EA - HEAT EXCHANGER ELEMENTS AND RELAYS
F35453 (July 2008) Page 20 of 68
3. If unable to check current draw, a resistance check may indicate a malfunctioning element.
A. Turn power switch off and disconnect power to machine.
B. Disconnect heat exchanger element lead wires and check resistance using a VOM.
C. If resistance is not correct, replace heat exchanger element.
4. Check steamer for proper operation.
MODEL VOLTAGE
WATTS PER
ELEMENT
CURRENT PER
ELEMENT
RESISTANCE PER
ELEMENT (OHMS)
C24EA6
208
1
450 2.20 96.1
240
1
600 2.50 96.0
480
2
600 2.20 128.0
C24EA10
208
1
600 2.90 72.1
240
1
800 3.30 72.0
480
2
800 2.90 95.9
1
Dual voltage elements.
2
480V Elements are connected in Wye configuration for 277V across each element.
NOTE: Values in table are nominal. Tolerance is ±10 %.