Vulcan-Hart ML-136058 Electric Steamer User Manual


 
MODEL C24EA - STEAM GENERATOR
F35453 (July 2008) Page 44 of 68
STEAM GENERATOR
REMOVAL AND REPLACEMENT
1. Turn off machine to drain steam generator. Allow
steamer to complete drain cycle.
A. Turn off water supply.
2. Remove FRONT, LEFT and RIGHT SIDE BASE
PANELS from generator base and COOKING
COMPARTMENT RIGHT SIDE PANEL as
outlined under COVERS AND PANELS.
3. Remove HEAT EXCHANGER.
4. Remove VACUUM RELIEF SOLENOID.
5. Disconnect compressions fittings then remove
condensate coil tubing.
6. Remove delime hose from water level probe
housing.
NOTE: Use new band clamps when connecting
hoses. See TOOLS.
7. Disconnect pop-off tubing then remove relief
valve from steam generator.
8. Disconnect compression fitting then remove the
fill piping assembly from steam generator fill tube.
9. Remove MOTORIZED DRAIN VALVE.
10. Remove HEATING ELEMENTS from
steam generator.
11. Remove high voltage control box from
steamer.
A. Disconnect electrical supply connections
from terminal block and ground.
B. Disconnect two wiring harness connectors.