MODEL C24EA - STEAM GENERATOR
F35453 (July 2008)Page 45 of 68
C. Remove four bolts securing high voltage
control box to frame.
12. Remove low voltage control box from
steamer.
A. Disconnect wiring harness connector
leading to cooking compartment controls.
B. Disconnect delime valve and drain valve
harness connectors from control board.
C. Remove four bolts securing low voltage
control box to frame.
13. Remove WATER LEVEL PROBES.
14. Remove ground wire from water level
probe housing.
15. Remove hardware securing steam
generator to frame (four places) then
remove generator.
16. Remove the following parts from steam
generator for reuse:
A. Drip shield (above elements).
B. Remaining pipe nipples, tees and elbows.
17. If removed or replacing steam generator,
install insulation around the generator.
Secure into position using high
temperature aluminum foil tape.
18. Reinstall parts removed in reverse order.
Apply pipe thread sealant to all pipe
threads connected to the steam generator.
19. Check steamer for proper operation.
Inspect all connections for leaks.
DELIMING
Refer to the Installation & Operation manual under
the MAINTENANCE section for specific instructions.
RIGHT SIDE SHOWN