Vulcan-Hart ML-136058 Electric Steamer User Manual


 
MODEL C24EA - WATER LEVEL CONTROL COMPONENTS
F35453 (July 2008)Page 23 of 68
DUAL WATER VALVES SHOWN
FILTERED AND NON-FILTERED
DUAL WATER SOLENOID
VALVES
NOTE: The filtered and non-filtered water solenoid valves are constructed as dual water valve assemblies. The
two water valve assemblies used on the steamer have different flow rates and should not be interchanged.
DUAL WATER VALVE FLOW RATES (GPM)
Filtered Water
(Steam Generator Fill)
Fast Fill/Flush Valve
(3SOL)
Slow Fill Valve
(4SOL)
4.8 0.28
Non-Filtered Water
(Condensate/Drain Cooling)
Cavity Condensate Valve
(2SOL)
Drain Cooling Valve
(1SOL)
3.8 3.8
1. Turn off machine to drain steam generator. Allow steamer to complete drain cycle.
A. Turn off water supply.
2. Disconnect incoming water to the dual water solenoid valve being replaced (filtered or non-filtered).
3. Remove RIGHT SIDE BASE PANEL as outlined under COVERS AND PANELS.
4. Note electrical connections then disconnect wires from solenoid valve.
5. Note hose connections then disconnect hoses from the outlet of solenoid valve.
NOTE: Use new band clamps when connecting hoses. See TOOLS.