Vulcan-Hart ML-136058 Electric Steamer User Manual


 
MODEL C24EA - WATER LEVEL CONTROL COMPONENTS
F35453 (July 2008) Page 24 of 68
6. Remove screws (2) securing dual water
solenoid valve to rear panel.
7. Reassemble parts removed in reverse order.
8. Verify water supply is connected to the correct
dual water solenoid valve (filtered or non
filtered).
9. Check steamer for leaks and proper operation.
MOTORIZED DRAIN VALVE
1. Turn power switch off.
A. Allow steamer to complete drain cycle.
B. If motorized drain valve has malfunctioned
and the steam generator will not drain
normally, refer to Drain Steam Generator
Manually for draining procedure.
Drain Steam Generator Manually
1. Turn off water supply to steamer.
2. Disconnect power to steamer allowing time for
water in steam generator to cool to 140EF
before attempting to manually open drain valve.
3. Remove RIGHT SIDE BASE PANEL as
outlined under COVERS AND PANELS.
4. Locate motorized drain valve found at the front
of steam generator.
5. Push in on the manual drain override knob to
disengage the gear set.
A. Rotate knob CW to manually open the
drain valve. When the slot in knob is
vertical, the drain valve is open. When the
slot in knob is horizontal, the drain valve is
closed.
B. Return manual drain override knob to the
closed position.
Removal
1. Turn off water supply to steamer.
2. Remove RIGHT SIDE BASE PANEL as
outlined under COVERS AND PANELS.
3. Remove motorized control assembly from drain
valve. Rotate motorized control assembly CCW
approximately 1/8 turn to disengage assembly
from drain valve.