Whirlpool KR-28 Range User Manual


 
- 7 -
643217910
10-PIN CONNECTOR
GND BAKE BROIL
TOP BURNERS
J1
DIRECT SPARK
IGNITION CONTROL
DIRECT SPARK IGNITION CONTROL
The Direct Spark Ignition (DSI) Control inter-
faces with the Electronic Oven Control for the
Bake, Broil, and Self-Clean functions. The DSI
also interfaces with the four cooktop burner ig-
nition switches, to provide ignition for the
cooktop.
The DSI control uses a self-diagnostic test to
verify that the oven ignition system is working
properly. It will also continually monitor the
flame presence within the oven. The DSI con-
trol operates on 102 to 132 VAC. All input and
output testing is performed at the J1 connec-
tor (see below).
J3
J4
T1
J1
T2
T3
T4
J2
J6
J5
J8
J7
1
2
3
4
6
7
9
10
J1
Bake Valve Output
Bake Input
Broil Valve Output
Valve Common
Neutral
Broil Input
Top Burner Input
Broil Burner Spark Output
L1
Bake Burner Spark Output
Chassis Ground
Left Rear Spark Output
Right Rear Spark Output
Left Front Spark Output
Right Front Spark Output
DIRECT SPARK IGNITION
ELECTRONIC CONTROL