Whirlpool KR-28 Range User Manual


 
- 25 -
BROIL
Done
Does the Broil
cycle function
properly?
Does the spark
continue after a
flame is present?
Does the Broil
burner establish
a flame and then
turn off?
Is 120 VAC
present from
J1-4 to J1-7?
Is 120 VAC
present from
J1-4 to J1-6?
Connect a DC voltmeter
to J1-3 (+) and J1-2 ().
Wait 40 seconds, then start a Broil
cycle. 6 seconds later, does
the meter indicate
8 to 18 VDC?
Measure the resistance at
the distribution valve. If different
than measured at the DSI control,
diagnose the wiring harness.
If resistances are the same as
measured at the DSI control,
replace the valve.
If the voltage is higher than
18 VDC, check the main wiring
harness for bad connections.
If okay, replace the
distribution valve.
yes
no
no
yes
no
no
yes
yes
yes
yes
yes
yes
yes
yes
no
no
no
no
Replace the gas
distribution valve.
Replace the DSI control.
Does spark
occur at the Bake igniter
but not the Broil?
Does spark
occur at the igniter?
Check the igniter for cracks in the
ceramics. If cracks are found, replace
the igniter. Diagnose the Broil igniter
wiring harness. If okay, replace the control.
The igniter position is
out of tolerance for the
proper ignition. Replace
the igniter and burner.
Check the igniter for
continuity. If not okay,
replace the igniter. If
the supply polarity is
correct, check the Broil
ignition wire for a loose
connection. If okay,
replace the DSI control.
Turn the ERC off.
Test the distribution valve
for continuity at J1-1 and J1-2,
then J1-2 and J1-3. Are
both resistances
216 ±30?
Diagnose the main
wiring harness and/or
the electronic oven
control (ERC).
Diagnose the ERC.
The DSI control will lockout
if a call for Bake & Broil
exists simultaneously.