Whirlpool KR-28 Range User Manual


 
- 14 -
4 (white)
10 (black)
J1 Connector
Broil Function
1. Set the voltmeter to read 120 VAC.
2. Program the range for the Broil operation.
3. If the top burners spark, proceed to step 4.
Touch the test leads to the J1 connector at
terminals 4 (white) and 10 (black). The AC
voltmeter should indicate 120 VAC. If not,
check for the proper voltage at the power
supply outlet, and check the main wiring
harness.
J1 Connector
* When power is applied to the range, a safety delay
of 40 seconds takes place before the direct spark
ignition control becomes operational. The opera-
tion will last for a period of 4 seconds, and the direct
spark ignition will again turn off (see the “Timing
Chart” for the oven burners on page 10).
5. Set the voltmeter to read between 8 and
18 volts DC.
6. Touch the test leads to the J1 connector at
terminals 1 (red) and 2 (orange). The DC
voltmeter should indicate between 8 and
18 volts DC*. If not, replace the DSI con-
trol.
J1 Connector
2 (orange)1 (red)