30
Special Set-Up Procedure (Continued)
7. Remove fasteners (M8 x 16 socket head screws
and M6 plain washers) that attach column
spacers to machine bed and remove spacers/
outer columns from machine bed. Figure 5-7A.
8. Remove fasteners (M8 x 20 socket head
screws) that attach spacers to columns, move
spacer down 100 mm [4 inches] to lower set of
mounting holes and re-attach spacers to
columns. Figure 5-7B.
9. Reverse procedure, Steps 7-1 to reassemble
machine.
Note – When installing upper assembly
back into machine (removed in Step 3), slide
upper assembly down into outer columns
until lead screws contact plastic nuts and
support upper assembly. Then, slowly turn
height adjustment crank counterclockwise
until two "clicks" are heard, one at each
plastic nut. Now the upper assembly can be
cranked down (turn height adjustment crank
clockwise) for installation of special nut on
bottom of each lead screw.
Figure 5-7 – Column Spacers/Columns