15
Installation and Set-Up (Continued)
11. Box size capacity (height) – at its factory
setting, the case sealer handles box sizes up to
620 mm [24-1/2 inches] maximum height. If
larger capacity is needed, the machine can be
adjusted to accommodate up to 725 mm [28-1/2
inches] high boxes. Refer to "Special Set-Up
Procedure – Outer Column
Re-Positioning", for set-up information.
12. Drive Belt Height – drive belt assemblies can be
raised 50 mm [2 inches] to provide better
conveying of tall boxes. Refer to "Special Set-
Up Procedure – Changing Drive Belt Height".
13. Pneumatic connection.
The case sealer requires a 6.5 bar gauge
pressure [95 PSIG] 75 liter/min @21°C, 1.01
bar [2.5 SCFM] compressed air supply. As
shown in Figure 2-5 an on/off valve, pressure
regulator, and filter are provided to service the
air supply.
The main air supply line should be connected to
the on/off valve by means of the barbed fitting
and hose clamp provided on the outer side of
the on/off valve as shown in Figure 2-5. The
customer supplied air hose (5/16 inch [8 mm]
ID) should be slipped over the barbed fitting
and clamped tightly in place.
If another type of connector is desired, the
fitting can be removed and replaced with the
desired 1/4-18 NPT threaded connector.
Always turn the valve "Off" when air supply
line is being connected or disconnected.
Figure 2-5 – Pneumatic Connection
Initial Start-Up of Case Sealer
After completing the "Set-Up" procedure, continue
through ""Operation", to be sure case sealer is
properly adjusted to run product.
Note
Machines outside the U.S. may be
equipped with 220/240 Volt, 50 Hz systems, or
other electrical requirements compatible with
local practice.
14. Electrical connection and controls – the electrical
control box shown in Figure 3-1, contains the
"On/Off" switch with pre-set breaker and can be
located on either side of the machine frame for
operator convenience. A standard three
conductor power cord with plug is provided at the
back of the electrical control box for 115 Volt, 60
Hz, 3.8 Amp electrical service. The receptacle
providing this service shall be properly grounded.
Before the power cord is plugged into 115 Volt,
60 Hz outlet, make sure red "Off" button is
depressed and that all packaging materials and
tools are removed from the machine. Do not
plug electrical cord into outlet until ready to
run machine.
To reduce the risk associated with mechanical and electrical hazards:
Turn electrical and air supply off and disconnect before performing any adjustments, maintenance or
servicing the machine or taping heads
WARNING