Maintenance (Continued)
Circuit Breaker
The case sealer is equipped with a circuit breaker
which trips if the motors are overloaded. Located
inside the electrical control box on the side of the
machine, the circuit breaker has been pre-set at
2.2 Amps and requires no further maintenance.
Air Line Filter – Figure 4-5
Periodically check the air line filter to drain water and
clean as necessary. Do not allow water to go above
the filter element.
Figure 4-5 – Air Line Filter
If circuit is overloaded and circuit breaker trips,
unplug machine from electrical power:
1. Determine cause of overload and correct.
2. Remove electrical enclosure cover.
3. Press the red "Reset" button and then the
green "Start" button.
4. Replace cover.
5. Plug in machine. Wait two minutes.
6. Press machine "On" button, on the side
guard, to resume case sealing.
Knife Replacement, Taping Head
See Section II, "Maintenance – Blade (Knife)
Replacement".