American Dryer Corp. AD-830 Water Dispenser User Manual


 
12
2. Electrical Specifications
* AWG Stranded Type Wire for individual lengths less than 100 feet (31 meters).
IMPORTANT: The water vending machine must be connected to the electric supply shown on the
data label that is affixed to the back of the water vending machine, at the upper right
hand corner. In the case of 208 VAC or 230/240 VAC, the supply voltage must
match the electric service specifications of the data label exactly.
WARNING: 208 VAC and 230/240 VAC ARE NOT THE SAME. Any damage done to water
vending machine components due to improper voltage connections will automatically
VOID THE WARRANTY.
NOTE: ADC reserves the right to make changes in specifications at any time without notice or
obligation.
F. UNPACKING/SETTING UP
ATTENTION: CHECK STATE and LOCAL LAWS REGARDING THE OPERATION OF
WATER VENDING MACHINES BEFORE INSTALLATION. SOME
STATES REQUIRE VENDORS TO NOTIFY THE DEPARTMENT OF
PUBLIC HEALTH or WEIGHTS and MEASURES CONCERNING THE
INSTALLATION OF THE MACHINE. FOLLOW ALL APPLICABLE
FEDERAL, STATE and LOCAL STANDARDS FOR DRINKING WATER
INSTALLATIONS.
ATTENTION: BE SURE THE INSTALLATION OF THIS MACHINE COMPLIES WITH
ALL LOCAL PLUMBING and ELECTRICAL CODES.
WARNING: DO NOT CONNECT ELECTRICAL POWER TO MACHINE UNTIL
REQUESTED.
AD-830
ELECTRICAL SERVICE SPECIFICATIONS (PER WATER VENDING MACHINE)
IMPORTANT: 208 VAC and 230/ 240 VAC ARE NOT THE SAME. When ordering, specify exact voltage.
NOTES: A. Fuse ratings are dual element time delay current limiting, class RK1 or RK5 ONLY.
B. Circuit breakers are thermal magnetic (industrial) type only. For others, calculate/verify correct
breaker size according to appliance amp draw rating and type of breaker used.
SERVICE
VOLTAGE
PHASE
WIRE
SERVICE
APPROX.
AMP DRAW
MINIMUM
WIRE
SIZE*
FUSING
Dual Element
Time Delay
CIRCUIT
BREAKER
50 Hz 60 Hz
115 2 15 14 12 25 30
208 2 8 7 14 12 15
230/240 2 8 7 14 12 15