American Dryer Corp. AD-830 Water Dispenser User Manual


 
5
SECTION II
SPECIFICATIONS/COMPONENT IDENTIFICATION
A. SPECIFICATIONS
Reverse Osmosis (R.O.) MembraneCapacity 1,200 gallons* 4.542.2 liters*
R.O. Pump 3/4 HP 0.55 kw
Dispensing Pump 3 gallon/minute 11.36 liters/minute
Drain Pump 3 gallon/minute 11.36 liters/minute
Water Vending Machines Per 20'/40 10/20
Water Vending Machines Per 45'/48 24/26
Voltage Available 115-240v 1Ø 50/60 Hz
Approximate Weight (Uncrated Empty) 1100 lbs. 498.9 kg
Approximate Weight (Uncrated Full/Capacity) 1700 lbs. 771.1 kg
Approximate Weight (Crated) 1200 lbs. 544.3 kg
Water Inlet Size 1/2 N.P.T. **
Drain Outlet Size 1/2 N.P.T. **
Storage Tank Size 93 gallons 352 liters
* These specifications are calculated at 2,000 ppm, total sodium chloride solution at 77º F (25º C) feed water
temperature and 160 PSI (11.03 bars) reverse osmosis (R.O.) pump pressure.
** MUST BE CONNECTED TO A MINIMUM 3/4” N.P.T. INLET WATER SUPPLY.
1. Minimum Pressure Inlet Flow Rate
4 gallons (15.14 liters) a minute at 35 PSI. (2.41 bars) back pressure or the equivalent of 9 gallons (34.06
liters) per minute at a free flowing 1/2” N.P.T. outlet at the intended location of the machine. This test
should be conducted with ALL other equipment connected to the same water line running to reflect true
flow.
2. Maximum Water Pressure
80 PSI. (5.51 bars). Install a pressure regulator if incoming water pressure exceeds this level. High inlet
pressure will irreparably damage filter housings and cause leaks in the system.