Cleveland Range 24/36CGM Electric Steamer User Manual


 
Operator’s Manual P/N-260AOZ-A
______________________________________________________________________________
12
Look to see if the generator has a buildup of scale greater
than the thickness of a business card or if the top is
beginning to peel off in layers. If either one of these condi-
tions is present, the generator needs to be chemically
descaled by your CLEVELAND AUTHORIZED SERVICE
AGENCY.
a. Inspect more frequently in areas where the water con-
ditions do not meet the Water Quality Requirements.
1. Change the boiler gasket every time you open the
boiler for liability reasons.
2. Check to see that all door fasteners are tight.
3. Check to see that all steam, water, and electrical con-
nections are secure. If any are loose contact your
authorized service agency to make the REPAIRS
It is in your best interest to maintain as many preventive
maintenance records as possible. When contacted by a
customer or service agency the manufacturer appreciates
having this information available.
The record keeping chart provided with the steam gen-
erator would assist you and your service agency. It will
help you record your maintenance and service history of
the equipment.
If you have any questions concerning the proper installa-
tion and maintenance of your CLEVELAND STEAM
COOKER call the Cleveland Service Department at (216)
4814900.