Cleveland Range 24/36CGM Electric Steamer User Manual


 
Operator’s Manual P/N-260AOZ-A
______________________________________________________________________________
17
Troubleshooting
OPERATORS TROUBLESHOOTING GUIDE
This troubleshooting guide includes a list of symptoms
that may be encountered during the operation and
maintenance. The first column on the left (problem)
describes these symptoms. The second column lists
possible causes for the problem listed in column one.
The third column lists remedies for the problems and
causes columns one and two. The causes and
remedies are listed in the am
Or they should be checked, with the least costly and
easiest to repair listed first. The third column also
refers to notes that are grouped at the end of the
troubleshooting guide. Refer to these notes when
instructed to do so. Do not try to correct a problem
that requires an authorized service representative as
this may adversely affect warranty coverage.
PROBLEM POSSIBLE CAUSE REMEDY/REFERENCE
Switch light does not turn on: Power turned off at main disconnects, Turn on power at main disconnect switch.
When POWER switch is pressed switch. SWITCH
On.
POWER switch light on and Water supply to steamer shut off. Open water supply valves.
Steam generator does not fill.
Water line strainer is clogged. Clean water supply strainer
Water sensors shorted by scale, Descale steam generator with USDA
Deposits. Approved descaler.
Inoperative controls or solenoid See note #1.
Steam Generator does not make No water in steam generator. See steam generator does not fill (above).
any steam.
Gas models only Turn off steam generator and open gas
Gas supply valve closed. supply valve. Refer to Service Manual.
Electric models only Descale steam generator with USDA
Heating elements covered with approved descaler
Scale.
Electric models only See note #1.
Heating elements damaged.
Water sensors covered by scale Descale steam generator with USDA
Deposits. Approved descaler.
Inoperative controls. See note #1.
Abnormal amount of steam hot water instead of cold water Make proper connections. Refer to
Coming from drain. Connected to condenser fitting Service Manual.
Water supply to condenser turned Open water supply valve.
off.
Condenser waterline strainer Clean out condenser water supply line.
is clogged. See note #1.
Water supply line to the con- Repair or replace solenoid. See note #1.
Condenser blocked, broken, or
leaking.
Inoperative condenser solenoid. Replace solenoid. See note #1.
Inoperative five controls. Turn off electricity at main disconnect
Switch. See note #1.
Steam and I or water draining Drain clogged or covered. Clean drain with USDA approved drain
around compartment door cleaner.
Door gasket or door parts worn. See note #1.