PROBLEM POSSIBLE CAUSE REMEDY/REFERENCE
Steamer not level See note #2.
Hot Water to con denser See note #2.
Reduced steam flow into cooking Steam generator scale buildup. Descale steam generator with approved
Compartment. Descaler
Steam nozzle scale buildup. See note #1.
Steam solenoids scale buildup See note #1.
Electric models only See note #4.
Voltage too low for unit.
Electric models only See note #1.
Faulty heating element or controls.
Steam flow does not stop when Operating in manual mode. Switch to timed mode for timer to be
timer stops. Effective.
Stuck open steam valve See note #1.
Inoperative five controls inside Turn off electricity at main disconnect
Cabinet. switch. See note #1.
Water leaking from bottom of broken or loose plumbing inside Turn off electricity at main disconnects
Cabinet. steamer cabinet. switch and close water supply valve(s).
See note #1.
Water leaking from water pipes Plumbing needs repair See note #3.
or drain lines.
Food takes too long to cook. Not enough steam movement in Make proper connections. Refer to Service
(Cook in perforated pans when compartment. Hot water con- Manual.
possible.) Connected to condenser line.
Pans too close to the bottom of Put pans in racks near top of cabinet.
cabinet.
Steam generator scale buildup. Descale steam generator with USDA
approved descaler
Compartment overloaded with Put less food in pan. Use fewer pans.
too much food.
Voltage too low for unit. See note #4.
Suggested cooking times are Extend cooking times for altitudes above
usually listed for cooking at sea Level 2500 FEET.
Compartment bottom dirty with Juices and /or food leaking from Put a solid pan under perforated pans to
food drippings. pans. catch drippings, or put less food in pan.
TROUBLESHOOTING NOTES
1. If problem is inside the steamer, call an authorized
Service representative Cleveland Range will not pay for
Non- warranty repair centers.
2. Proper installation of the Convection Steamer
Responsibility of the owner or installer Refer to Cleveland
3. Repair to external wiring should be done by a Licensed
Electrician.
4. For more information on products and services, contact