Cleveland Range 24/36CGM Electric Steamer User Manual


 
Operator’s Manual P/N-260AOZ-A
______________________________________________________________________________
13
Descaling is the most important maintenance you
can perform on a steam cooker, and is required by
the Cleveland Range warranty.
The Descaling Pump System circulates DISSOLVE
descaling liquid through the boiler of the steamer.
Recirculating the descaling liquid provides a faster
and more thorough cleaning process than the
conventional soaking process.
The Descaling Pump System consists of a
submersible pump, a 5-gallon reservoir pail,
Hand-Hole plate with ports, the feed and drain
hoses, and the temporary hose couplings
necessary to connect the system to the Classic
Series Cleveland Steamers.
Descaling Procedure
Convection Steamers
Pressure Steamers
SteamPro/Convection Pro
Modular Boiler Bases
(Using the Descaling
Pump System)
Cleveland Range has developed the Descaling
Pump System for owners of the Classic Series
Convection Steamers, Pressure Steamers and
SteamPro/Convection Pro series steam
cookers.
The Pump System provides a fast,
highly efficient way to descale Cleveland Steam
Cookers. The descaling Pump Kit includes a
temporary hand-hole plate that is equipped with
two descaling ports, one for the inlet and one
for the outlet. This is to be used only for the
Pump Kit and replaced at the end of the
procedure.