Dacor ER30D-C Cooktop User Manual


 
13
Installation Instructions
Installation Instructions
Connecting the Wiring to the Range
Refer to the range rating label (see page 3) for power
requirements.
There are four possible ways to wire the range:
4 Wire Conduit
3 Wire Conduit (where local codes permit)
4 Wire Appliance Cord (where local codes permit)
3 Wire Appliance Cord (where local codes permit)
The sections below and on the following pages give directions for
connecting each type of wiring harness.
WARNING
Do not connect the green appliance wire to the neutral (white)
supply wire unless local building codes permit.
Connecting Conduit to the Range
NOTE: See pages 16 and 17 for instructions to connect an
appliance cord to the range.
Remove the range electrical access cover from the back of
the range.
If using a 4 wire connection, loosen the grounding screw and
remove the neutral to ground jumper link.
Remove the nut from the conduit strain relief (not included).
Slide the wires and the end of the strain relief into the hole on
the bottom of the range electrical box.
Before connecting the wires, slide the strain relief nut over
the wires and thread it onto the conduit strain relief inside the
box. Tighten into place.
Connect the white wire to the neutral terminal in the box.
Connect the black wire to the L1 power supply terminal.
Connect the red wire to the L2 power supply terminal.
If using a 4 wire connection, connect the green wire to the
grounding screw inside the box.
Replace the range electrical access cover.
1.
2.
3.
4.
5.
6.
7.
8.
9.
10.
Loop and
Spade Terminal
Connections
Bare Wire
Connections
3 Wire Conduit Connection -
Where Local Code Permits
Conduit Strain
Relief Nut
Red Wire
White Wire
Black Wire
Neutral Terminal
L1 Terminal
L2 Terminal
Jumper Link
4 Wire Conduit
Connection
Conduit Strain
Relief Nut
Red Wire
White Wire
Green Wire
Neutral Terminal
L1 Terminal
L2 Terminal
Jumper Removed
Black Wire
Grounding Screw