Planning the Installation
WARNING
IMPORTANT: Observe all governing codes and ordinances
during planning and installation. Contact your local building
department for further information.
Electrical Requirements
IMPORTANT: The information below applies only to free standing
units equipped for use in the U.S.A. and units with the self
rimming option.
It is the owner’s responsibility to ensure that the electrical
connection of this appliance is performed by a licensed
electrician. The electrical installation, including minimum supply
wire size and grounding, must be in accordance with the National
Electric code ANSI/NFPA 70-1993* (or latest revision) and local
codes and ordinances. A copy of this standard may be obtained
from:
National Fire Protection Association
1 Batterymarch Park
Quincy, Massachusetts 02269-9101
The correct voltage, frequency and amperage must be
supplied to the appliance from a separate, grounded, circuit
that is protected by a properly sized circuit breaker or time
delay fuse. Refer to the ratings on the range rating label.
ER30D/ER30DSR ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required Total Connected Load
240 Vac, 60 Hz, 30 Amps 5.6 kW (23 Amps)
The ratings above are for reference only -
refer to the range rating label (see page 3)
Consult local building codes for the type and minimum wire
gauge to use for the power requirements listed on the rating
label.
Suggested wiring color code: Black, white, red and green.
The wiring needs to be long enough to allow the range
to be pulled out from the wall for service, while remaining
connected. See page 12 for further details.
The wiring to the range must:
Have a minimum rating of 250 Volts @ 30 Amps
Include a strain relief
Be terminated by tinned leads, closed loop terminals or
open ended spade lugs with upturned ends
Where local code permits, a three (3) or four (4) wire
appliance cord may be used. The appliance cord must:
Be UL listed type SRD or SRDT
Be equipped with a NEMA 14-50P 4 wire plug or, where
local code permits, a NEMA 10-50P 3 wire plug.
Prior to range installation, have a licensed electrician install a
conduit junction box or electrical receptacle according to the
type of wiring used.
NEMA 14-50P Plug
NEMA 10-50P Plug
Electrical Requirements -
Freestanding Units for Use in Canada
It is the owner’s responsibility to ensure that the required
4 wire electrical outlet is installed by a licensed electrician
as specified below prior to range installation. The electrical
outlet installation, including minimum supply wire size and
grounding, must be in accordance with all governing codes
and ordinances.
The correct voltage, frequency and amperage must be
supplied to the appliance from a separate, grounded, circuit
that is protected by a properly sized circuit breaker or time
delay fuse. Refer to the ratings on the range rating label.
ER30D-C ELECTRIC CIRCUIT REQUIREMENTS
Circuit Required Total Connected Load
240 Vac, 60 Hz, 30 Amps 5.6 kW (23 Amps)
The ratings above are for reference only -
refer to the range rating label (see page 3)
Freestanding ranges equipped for use in Canada come pre-
wired with a 4 wire appliance cord and NEMA 14-50P plug.
Do not modify the factory wiring. The plug is designed to plug
directly into a NEMA 14-50R electrical receptacle installed by
a licensed electrician according to the above specifications.
Gas Supply Requirements
Check your local building codes for the proper method of
installation. In the absence of local codes, this appliance
should be installed in accordance with the National Fuel Gas
Code ANSI Z223.1.
Be certain that the appliance being installed is correct for
the gas service provided (natural gas or LP gas). Also, if
operating the range at an altitude above 4000 ft. (1219 m)
make sure it is equipped for high altitude operation. Refer to
the range rating label and the table on page 3 to determine
the correct model.
See the table below for gas supply pressure requirements.
The regulator inlet accommodates a 3/4” gas line. The range
ships with a 1/2” to 3/4” adapter connected to the regulator.
GAS SUPPLY PRESSURE REQUIREMENTS
Gas Type Manifold Pressure
Minimum Gas
Supply Pressure
Natural Gas 5” Water Column 6” Water Column
Propane (LP) 10” Water Column 11” Water Column
The ratings above are for reference only -
refer to the range rating label (see page 3)
NEMA 14-50R Receptacle