Fagor America RFA-365 DF Range User Manual


 
11
The measurements of the space in which the range is to be installed must
coincide with those indicated below.
The ranges may be installed directly next to existing countertop high cabinets
(36” or 91.5 cm from the  oor).
For seamless integration of the range, the cooktop should be leveled with the
countertop. This can be done by raising the range using the adjustment screws
on the legs.
ATTENTION: The range CANNOT be installed directly adjacent to kitchen walls,
tall cabinets, tall appliances, or other vertical surfaces greater than 36” (91.4 cm)
high. The minimum side clearance in such cases is 6” (15.2 cm).
Wall cabinets with minimum side clearance must be installed 18” (45.7 cm)
above the countertop with countertop height between 35 ½” (90.2 cm) and 37 ¼”
(94.6 cm). The maximum depth of wall cabinets above the range must be 13”
(33.0 cm).
The oven capacity is as follows:
Model RFA-365 DF: 3.7ft (105 L) Model RFA-244 DF: 1.97ft (56 L)
INSTALLATION DIMENSIONS
2.2
RFA-365DF RFA-244DF
1 ”
37
64
0 ”
15
16
1 ”
37
64
1 ”
37
64
35 ”
7
16
35 ”
7
16
5 ” –
5
16
6 ”
57
64
5 ” –
5
16
6 ”
57
64
23 ”
5
8
23 ”
5
8
23 ”
5
8
30 ”
1
8
30 ”
1
8
23 ”
5
8
23 ”
5
8
23 ”
5
8