Fagor America RFA-365 DF Range User Manual


 
9
This range should only be installed according to the manufacturer’s instructions.
Installation should only be attempted by an authorized professional.
This range must be installed in accordance with the norms and standards of the
country where it is being installed. The installation of this appliance must conform
to local codes and ordinances. In the absence of local codes, Installations must
conforms to American National Standards, National Fuel Gas Code ANSI Z223.1
– latest edition** or B149.1.
The range, when installed, must be electrically grounded in accordance with local
codes or, in the absence of local codes, with the National Electrical Code, ANSI/
NFPA 70.
This range must be used with the pressure regulator provided. The regulator will
need to be properly installed in order to be easily accessible when the appliance
is installed in its  nal location. The pressure regulator must be set for the type of
gas being used. The appropriate  tting must be determined based on the size of
your gas supply line, the  exible metal connector and the shut-off valve.
The range must be isolated from the gas supply by closing its manual shut-
off valve during any pressure testing of the gas supply piping system at test
pressures equal to or less than ½ psi (3.5 kPa).
All openings and holes made in the wall and  oor behind or under the range
should be securely sealed before installing the appliance.
A manual valve should be installed in an accessible location in the gas line outside
of the range in order to turn the gas on and off when necessary.
2. INSTALLATION & ELECTRICAL
AND GAS CONNECTION
BEFORE INSTALLATION
2.1