Fagor America RFA-365 DF Range User Manual


 
18
SETTING THE MINIMUM FLAME
The  ame on the lowest output level is regulated by the factory. When the injectors
have been replaced or there are conditions of unusual gas pressure, it may be
necessary to regulate a minimum size  ame. Please follow the below directions:
Turn the burner knob to the minimum position.
Use a thin blade screw driver to turn the screw located in the brass shaft.
Turn the screw fully clockwise, then turn it counter-clockwise 1/4 turn for the
Dual Burner and 1/8 turn for all other burners. The result should be a small,
stable  ame which is uniform around the entire burner ring. If not, turn the
screw counter-clockwise until satis ed with the size of the  ame.
Put the knob back on the range and turn it quickly from the maximum
position to the minimum position, checking that the  ame does not go out.
For burners with safety valves, make sure the regulation obtained is suf cient
to maintain heating of the thermocouple. If not, increase the minimum.
THE BURNERS REQUIRE NO REGULATION OF THE AIR FLOW THROUGH OR
AROUND THE BURNER. ANY OF THE FOLLOWING ARE CONSIDERED TO BE
ABNORMAL OPERATION AND MAY REQUIRE SERVICING:
Yellow tip on the hob burner  ame.
Soot buildup on cooking tools.
Burners not igniting properly.
Burners failing to remain lit.
• Burners ames extinguished by opening oven door.
Gas valves are dif cult to turn.
IN CASE THE RANGE FAILS TO OPERATE CORRECTLY, CONTACT THE
SERVICE HOTLINE LISTED ON THE BACK OF THIS MANUAL.