Frymaster 24G Series Fryer User Manual


 
24G SERIES FLATBOTTOM GAS FRYERS
CHAPTER 1: SERVICE PROCEDURES
1-11
IMPORTANT (High-Limit): When installing new high-limit, ensure the capillary tube and
bulb are positioned properly with the mounting hardware installed prior to tightening the
compression nut. Once tightened, the capillary tube cannot be repositioned.
IMPORTANT (Temperature Probe):
When installing new temperature probe,
ensure probe is positioned properly with the
mounting hardware installed (current
production systems), or 1/8" from frypot
bottom (older systems), prior to tightening
the compression nut. Once tightened, the
probe cannot be repositioned.
1.7.2 Removing/Replacing Rocker Switches
1. Disconnect the fryer from the electrical supply.
2. If switches are located on front panel or control box, remove the screws securing panel. Do not
allow the panel to hang on the switch wiring harness; use some type of support.
3. Depress the retaining clips (see illustration below) and push the switch out of the slot. If there is
a switch-guard present, retain it for installation of the replacement switch.
Depress clips on each
end to remove switch
from control panel.
When connecting wires to
replacement switch, pass the wires
through the switch guard (if
applicable) before connecting to
switch.
4. Remove wires one at a time from the switch being removed and connect to the replacement
switch until all wires are transferred.
5. Reverse the above steps for reassembly.
In older fryers, ensure probe tip is 1/8" from
frypot bottom for proper temperature sensing.
Frypot Bottom