Part # MPSM07 (03/24/08)Page 12
CAUTION:
DISCONNECT ALL OVENS FROM ELECTRI-
CAL SUPPLY BEFORE
SERVICING.
POWER FAILURE:
IN THE EVENT OF A POWER
FAILURE, NO ATTEMPT SHOULD BE MADE
TO OPERATE THIS OVEN.
ELECTRICAL CONNECTIONS
A separate electrical connection must be supplied for each
oven. Connection to the electrical service must be grounded
in accordance with local codes, or in the absence of local
codes with the National Electrical Code, ANSI/NFPA 70, or the
Canadian Electrical Code, CSA C22.2, as applicable.
A strain relief for the power supply cord is required. The
installer must supply a cord bushing that meets local and
national codes.
For 120VAC usage a cord and NEMA 5-15P plug is provided.
Garland recommends a separate 15 Amp service for each
oven. Ovens for 120V service are supplied with a three
pronged plug for your protection against shock hazard and
should be plugged directly into a properly grounded three-
prong receptacle.
DO NOT CUT OR REMOVE THE GROUNDING PRONG FROM
THE PLUG.
A wiring diagram is axed to the rear of the oven and
included in this booklet.
ELECTRIC OVENS - SHIPPED WITH KNOCKOUT
PLATE FOR POWER SUPPLY
REMOVE THIS SCREW TO ALLOW
ACCESS TO THE TERMINAL BLOCK (ELECTRIC OVENS)
OR CORD CONNECTIONS (GAS OVENS)
Figure 4.