Garland MP-GD-10-S Oven User Manual


 
Part # MPSM07 (03/24/08)Page 40
When the water system is energized, and the cavity is at a
temperature of 225°F (107°C) or higher, condensation mist
should appear from the water nozzle located above the fan,
and behind the air bae plate (not shown).
Nozzle
The Timer is a solid state timer on the control compartment
sidewall.
Deluxe (Fast Panel Moisture Control)
Moisture is controlled by pre-programmed choices selected
during the product cook cycle sequence. (See product cook
programming in the Operation Manual section). Additional
moisture can be manually selected using the moisture key
pad.
COMPONENT IDENTIFICATION
Moisture Control
Mechanical Moisture Control
The Moisture system applies water through the solenoid
in 1 second cycles.
The scale settings are in seconds.
Set to the low position, the water will cycle once every 60
seconds.
Set to the 60 second position, the water will cycle 6 times
in 1 minute.
60
55
50
45
40
35
30
25
20
15
LOW
The control increases the cycle time frequencies by rotating in
a clockwise
Water pressure check:
Minimum water feed pressure: Fully open the pressure
regulator control knob to determine what the line pressure is.
The gauge should read at least 30 psi.
Regulator pressure: The regulator should be set at 20 psi
when the spritzer valve is energized.
One way to determine if water is being injected is to monitor
the pressure gauge. The static pressure reading will drop 6
- 10 psi when the solenoid valve is opening, or cycling.