Garland MP-GD-10-S Oven User Manual


 
Part # MPSM07 (03/24/08)Page 54
TESTING & TROUBLESHOOTING
Direct Spark Ignition Detail
MPO Direct Spark Ignition Specications and Module Box Connections
Manufacturer JOHNSON CONTROLS INC.
Vendor Part # G760BAD-1
Ignition Type Direct Spark
High Voltage Cable Wire Stranded
Ignition Source High Voltage Spark
Maximum Cable Length 48” (1,220mm)
Flame Detection Means Flame Rectication
Flame Detection Types Remote Sensing
Minimum Flame Current 0.3 Microampere
Flame Failure
Response Time
0.8 Seconds Maximum
Spark Gap 0.1” (2.5mm)
Ignition Retrials 3
Safety Times 4 Seconds
Waiting Times 0 Seconds
Interpurge 30 Seconds
Loss Of Flame Signal Retrials 4 (Five Total Ignition Attempts)
Operation Current
24 VAC, 50/60 HZ, Nominal, 0.2A
Nominal + Main Valve
Contact Rating (MV) 2A Continuous, 5A Inrush
Ambient Operating And
Storage Fluttered
-40 to 158 °F (-40 to 70°C)
Humidity 95% RH non-condensing
Wire Connections
Spark Options
RAJAH Connector
GROUND
5
LED
THS 2
M.V. 3