Part # MPSM07 (03/24/08) Page 45
• If the actual temperature inside the oven exceeds the
set temperature by 50°F, the display will show “HI TEMP”
and the alarm will sound. The fan will continue to run,
however, power to the heaters will be cut.
• If the actual temperature sensed inside the oven exceeds
575°F, the control will change to “HELP” and the alarm will
sound continuously. All control operations will shut down
except the alarm.
• NOTE: The control will need a complete power down and
restart (unplug/plug in oven) before any control functions
will become operational. If the problem persists, contact a
service technician.
• In the event of a temperature probe failure, the control
will become inoperative and the display will show “PROBE
ERROR”. Once the problem is corrected, the control must
be cycled On/O (using the ON/OFF key) in order to
become operative again
DIAGNOSTIC PROCEDURES