Graco 310554V Water Dispenser User Manual


 
Installing the Control Assembly
310554V 11
Installing the Control Assembly
To install the control assembly:
Prepare to install the control assembly
Mount the control assembly
Ground the control assembly (electrically)
Connect control assembly to a power source
Check resistance between the control assembly and
a true earth ground.
Preparing to Install the Control
Assembly
Before installing the control assembly:
See component manuals for specific data on com-
ponent requirements, such as a robot. Data pre-
sented here pertains to the PrecisionSwirl control
assembly only.
Have all applicable documentation available during
installation.
Use only the Graco PrecisionSwirl control assembly
with the PrecisionSwirl applicator.
Mounting the Control Assembly
1. Select a location to mount the PrecisionSwirl control
assembly. Keep the following in mind:
Allow sufficient space for mounting and using the equip-
ment:
Mount the control assembly approximately 24-67 in.
(0.6-1.7 m) above the floor.
Make sure all cables reach components without
strain.
Make sure there is sufficient space for repair, main-
tenance, and operation of the robot and applicator.
The National Electrical Code requires 3 ft (91.4 cm)
of open space in front of the control assembly.
Make sure there is sufficient clearance around the
control assembly for running fluid lines and cables to
other components.
Make sure there is easy and safe access to an
appropriate electrical power source.
2. Secure the PrecisionSwirl control assembly with
four 1/4 in. bolts through the 0.31 in. diameter holes
in the mounting flanges. See F
IG. 4 for the mounting
hole spacing in the control assembly.
ELECTROCUTION HAZARD
Installing and servicing this equipment requires access
to parts which could cause an electric shock or other
serious injury. Have only qualified electricians access
the control assembly.
EQUIPMENT MISUSE HAZARD
The PrecisionSwirl control assembly weighs approxi-
mately 23.5 lb (10.7 kg). Exercise care when mounting
and handling the control assembly to prevent equip-
ment damage or personal injury.