Graco 310554V Water Dispenser User Manual


 
Verifying Ground Continuity
20 310554V
Verifying Ground Continuity
Verifying Ground Continuity
Verify ground continuity between:
True earth ground and the control assembly ground
terminal
The orbital dispenser and the robot
Adjusting the Orbital Dispenser
The PrecisionSwirl orbital dispenser is calibrated at the
factory. No adjustment is required during initial setup.
Before applying power, read the reference information
provided about controls and indicators to become famil-
iar with the equipment.
Inspecting the Orbital Dispenser
Inspect the orbital dispenser cables, material, and air
hoses daily for leakage and other visible damage.
Grounding the System
The following grounding instructions are minimum
requirements for a basic dispensing system. Your sys-
tem may include other equipment or objects which must
be grounded. Check your local electrical code for
detailed grounding instructions for your area and type of
equipment. Your system must be connected to a true
earth ground.
1. Pump: connect a ground wire and clamp to a true
earth ground as shown in separate pump manual.
2. Orbital Dispenser: obtain grounding through the
motor cable assembly.
3. Fluid and air hoses: use only electrically conductive
material and air hoses.
4. Dispense gun: obtain grounding through the con-
nection of the hose, or cable.
5. Air compressor: follow the manufacturer’s recom-
mendations.
6. Object being sprayed: according to local code.
7. Fluid supply container: according to local code.
FIRE AND EXPLOSION HAZARD
To reduce the risk of a fire, explosion, and serious
injury, proper electrical grounding of every part of your
system is essential. Read the warning section, FIRE
AND EXPLOSION HAZARD, on page 5 and follow the