Graco 310554V Water Dispenser User Manual


 
PrecisionSwirl Module Operation
310554V 21
PrecisionSwirl Module Operation
Reading the PrecisionSwirl Control Assembly Controls and
Indicators
Table 1 describes the controls on the PrecisionSwirl control assembly. See FIG. 12 for an illustration of the controls
and indicators.
Table 1. Control Assembly Controls
Table 2 describes the indicators on the PrecisionSwirl control assembly. See F
IG. 12 for an illustration of the controls
and indicators.
Table 2. Control Assembly Indicators
Button/Switch What it does
MAIN ON/OFF Switch Controls power to the system.
In the MAIN ON (I) position, system power is turned on.
n the OFF (0) position, system power is turned off.
Control Select Switch
AUTOMATIC / MANUAL
Switches the orbital dispenser to automatic or manual control.
In the AUTOMATIC position, the orbital dispenser is controlled from a
remote source, such as a robot, via an interface cable.
In the MANUAL position, the orbital dispenser is controlled directly from
the control assembly front panel.
RUN / ENABLE Button Pushing the RUN/ENABLE (black) button starts the orbital dispenser motor
in manual mode or enables the motor to be started in automatic mode.
STOP Button Pushing the STOP (red) button removes power from the orbital dispenser.
MANUAL SPEED CONTROL Knob
(potentiometer)
Regulates the motor speed of the orbital dispenser in the manual control
mode.
Rotating the control knob clockwise increases motor speed.
Rotating the control knob counter–clockwise decreases motor speed.
Button/Switch
Indicator
Light is Meaning
POWER (white ON Power is on.
OFF Power is off.
RUN (green) ON PrecisionSwirl orbital dispenser is ready for operation, or is
operating in manual control mode.
OFF PrecisionSwirl orbital dispenser is not ready for operation, or
is not operating in manual control mode.
MOTOR FAULT (red) ON Motor is not rotating. Or, the motor is rotating below the mini-
mum speed.
OFF Motor is functioning properly.