Grundig HDM 2370 P CI Refrigerator User Manual


 
- 7 -
- 7 -
2.5 Software query
Control unit
If necessary, you can activate the indication of the software version of the con-
trol unit manually:
• Press any two keys on the control unit of the head-end station simultaneously
until the display goes dark and
the software version, e.g. “
V 37
” appears.
3 Assembly
3.1 Installing the cassette
Caution
– Ensure the head-end station is mounted so it will not be able to vibrate.
Avoid, for example, mounting the head-end station onto a lift shaft or any
other wall or floor construction that vibrates in a similar way.
– Before installing or changing a cassette unplug the power cable from the
mains power socket.
Remove the fastening screws 1 of an unoccupied slot from the bracket of the
head-end station.
• Insert the cassette in this slot and push it into the housing.
Align the cassette and apply slight pressure to connect it to the connections of
the board and the HF bus bar.
• Fasten the cassette with the 1 screws.
+24
BREITBA
C101
L104
L100
L101
L103
C100
LNC-
+18V
ROT
+18V
Anschl.
GRUEN
INPUT OUTPUT OUTPUT INPUT

