Hobart FT1000S-ER Dishwasher User Manual


 
– 27 –
Final Rinse
For FT1000 Base models, the required minimum hot water temperature for the
nalrinseis110°Fwhenanelectricorsteamboosterheaterissupplied(same
connectionpointforll).ForFT1000EnergyRecoverymodels,theminimumcold
watertemperatureforthenalrinseis55°Fwhenanelectricorsteambooster
heater is supplied. The energy recovery models have a single 1” NPT female cold
water connection point.
Remove the nal rinse arms and purge the nal rinse system
prior to operation. This will reduce the possibility of clogging the nal rinse
nozzles. To properly purge the unit, activate the nal rinse for 3 to 5 minutes
and then reinstall the rinse arms.
Drain
For machines without Auto Clean or Auto Delime, connect the drain at the 2” NPT
threadedttinglocatedateithertheloadendortheunloadendofthemachine.
NOTE:Theplugttingandthethreadeddrainttingcanbeinterchangedtoreverse
the drain end of the machine.
On machines equipped with Auto Clean and/or Auto Delime, the master drain
assembly is located at the unload end of the machine. Connect the drain at the 2”
NPTthreadedtting.SeeRELOCATINGMASTERDRAINTOLOADEND(page
14) if machine drain is to be located at load end.
NOTE: On machines equipped with Auto Clean and without the ASR section, the
master drain assembly is located at the unload end only.
Ifagreasetrapisrequiredbycode,thedrainshouldhaveaowrateof38gallons
per minute.
Line Strainer
Line strainers on the machine should be cleaned after installation and within the
rstweekofoperation.Thelinestrainerswillcollectoilsandothercontaminants.
Cloggedlinestrainerswillcauserestrictionstotheowofwaterorsteamandwill
reduce overall performance of the machine.
Steam Supply (When Equipped)
Check all steam lines for leaks, particularly unions. Tighten if necessary.
Thesteamsupplymustbe10-45psigowingpressureatthedishwasher.Machines
haveasingle1½”NPTfemalettingforconnectionunderneaththeunloadend.
NOTE: Ifavailable steam pressure isless than 10 psiowing at themachine,
operationalcharacteristicsmaybelimitedbecauseofinsufcientdeliveryofsteam.
If this occurs, contact Hobart Warewash Technical Support