If the conveyor is tracking straight but travels closer to the front (door side) or toward
the rear of the machine, then do the following:
If tracking closer to the front, tighten the adjusting bolt on the front take-up unit.
If tracking closer to the rear, tighten the adjusting bolt on the rear take-up unit.
Run the conveyor for 20 minutes. During this time, it may be convenient to perform the
booster thermostat calibration described under “Calibrating the Booster Thermostat”
in the Miscellaneous section of this manual. After running the conveyor for 20
minutes, stop the conveyor and check the tension. Proper tension is achieved when
the conveyor rollers run freely on the bottom track and, by grasping a conveyor rod
near the middle, the conveyor cannot be lifted vertically so that the conveyor rollers
clear the top of the track on the unload end.
If additional tension is needed on the conveyor (after it has been centered),
tighten both the front and rear take-up units the same amount.
MISCELLANEOUS
NOTE: Check all bolts and connectors to make sure they are tight.
Vent
Do not step on top chamber covers when installing vent.
Install minimum of 24” x 24” canopy vent hood (supplied by others) over top of
machine’s exhaust fan housing maintaining a 6” air gap. For FT1000 Base machines,
the building’s exhaust fan should provide 550 cubic feet per minute (cfm, at standard
air conditions). For FT1000 Energy Recovery machines (with and without Blower
Dryer), the building’s exhaust fan should provide 750 cubic feet per minute (cfm,
at standard air conditions).
The air dampers are factory set. After machine is placed in full operation with
customer running ware, if adjustments are required, refer to the service manual or
contactyourlocalHobartServiceofce.