Hobart H0210G2 Convection Oven User Manual


 
– 12 –
TEMPERATURE AND TIMER CONTROL SETTINGS
The temperature and timer controls are factory set
to degrees Fahrenheit with minutes set and minutes
remaining. If desired, the controls can be changed
to degrees Celsius and/or hours and minutes
remaining as follows:
1. Press TEMP. and enter 99 on the number
keypad. Do the same for TIMER, STEAM and
DELAY. Wait 5 seconds for displays to change
to 0.
2. Press TEMP. and then enter the following:
0 for Fahrenheit with minutes set and
minutes remaining (factory setting)
1 for Celsius with minutes set and minutes
remaining
2 for Fahrenheit with hours and minutes
remaining
3 for Celsius with hours and minutes
remaining
3. Press QUICK SET, enter 0 on the number
keypad and then press START.
4. Turn OFF the power switch for at least 3
seconds and then turn it back ON. The oven
should now be in the temperature and timer
mode you chose.
5. If needed, attach the HOURS-MINUTES label
(located on the inside of the front control door)
to the digital control panel.
PL-53621
SET
TEMP.
OVEN
TEMP.
Actual Temperature In Oven
Max.Temp. 525 F / 274 C
HEAT ON
OO
TIMER
STEAM
DELAY
(AIRFLOW)
ON
Seconds
ON
Minutes
Minutes Set
Remaining
Heat is disabled
during this delay
ON
QUICK
SET
Number 0-84
TEMP.
CLEAR
or SET
TIMER
CLEAR
or SET
STEAM
CLEAR
or SET
DELAY
CLEAR
or SET
QUICK
SET
START
STOP
RESUME
CLEAR
or SET
1
23
4
5
8
6
7
90
OPEN (LIT)
VENT POWER PULSE
AIRFLOW
CLOSED (OFF) OFF OFF
ON AUTO