Hobart ML-130193 LXeR Dishwasher User Manual


 
– 10 –
CHEMICAL SANITIZER (LXeC & LXePR)
Items such as pewter, aluminum and silver will be attacked by sodium hypochlorite
(bleach). Therefore, chemical-sanitizing dishwashers should not be used to wash such items.
On models LXeC & LXePR, the chemical sanitizer pump is factory-set for use with 6% sodium hypochlorite
solution.
If 8.40% sodium hypochlorite solution is to be used, contact your local Hobart Service Ofce.
On LXeC models, place a 1-gallon bottle of 6% or 8.40% sodium hypochlorite solution (bleach) in a suitable
location no higher than 10 inches off the oor. Do not pre-mix sanitizing solution with water or any other
liquid.
On LXePR models, place a sanitizer approved for potable water rinse machines in a suitable location no
higher than 10 inches off the oor. Do not pre-mix sanitizing solution with water or any other liquid.
Never premix a wetting agent with the sanitizing solution. Mixing may cause
hazardous gas to form.
Remove the sanitizer bottle cap and place the white delivery tube in the sanitizer container. Be sure to
push the delivery tube standpipe completely to the bottom of the container. Check to make sure there are
no obstructions or kinks in the delivery tube.
Frequently check your sanitizer bottle to make sure there is a sufcient chemical supply.
CHECKING SANITIZER CONCENTRATION
Verify there is sufcient chemical supply in the sanitizer bottle and that the delivery tube standpipe is
inserted completely to the bottom of the chemical container. Place a glass rack, with glasses, in the
machine.
On LXePR models, the PuriRinse feature must be deactivated to properly check the sanitizer concentration.
To deactivate PuriRinse, press and hold the WASH key for ve seconds until wash cycle starts.
On LXeC models, press the WASH key to run a cycle. At the end of the cycle, open the door.
Follow the directions precisely that are on the litmus paper vial and test the water on the surface of the
bottom of the glasses. Concentration should be 50 p.p.m. minimum to 100 p.p.m. maximum.
If reading is incorrect, contact your local Hobart Service Ofce or chemical provider for adjustments.
DELIMING SOLUTION
All LXePR and LXeR models are equipped with an automatic deliming system. At installation, a qualied
Hobart Service technician or your chemical supplier must adjust the total water hardness setting to
properly set the delime intervals.
Remove the deliming agent bottle cap and put the black delivery tube in the container.
Be sure to push the delivery tube standpipe completely to the bottom of the container. Check to make
sure there are no obstructions or kinks in the delivery tube.