DIAGNOSTIC/ERROR MESSAGES
Error Display Description
Door Open Door Open
Displayed when the door of the machine
is opened.
Clogged/
Blocked Wash
Arm
WASH ARM ALERT
- Remove & clean arm
- Check nozzles
- Replace arm
- Close door
Displayed if wash arm is blocked or
clogged which would result in poor wash
results. Follow on-screen instructions.
Low Rinse
Temperature
LOW RINSE TEMP
After two consecutive low temperatures,
if problem occurs on the third
consecutive cycle, the error will display.
The machine will continue to run cycles.
Low Rinse
Temperature
(10 In A Row)
LOW RINSE TEMP
Check Water Input
If the Low Rinse Temperature error
occurs for 10 consecutive cycles, the
error will change. The machine will
continue to run cycles.
Wash
Thermistor
Error
WASH TEMP SENSOR
Service Required
(Service Phone Number)
OPEN or SHORT
Error displayed if wash temperature
probe is out of range. The machine will
continue to run cycles.
Booster
Thermistor
Error
BOOSTER TEMP SENSOR
Service Required
(Service Phone Number)
OPEN or SHORT
Error displayed if booster temperature
probe is out of range. The machine will
continue to run cycles. (LXeH & LXeR
models only.)
Final Rinse
Thermistor
Error
RINSE TEMP SENSOR
Service Required
(Service Phone Number)
OPEN or SHORT
Error displayed if nal rinse temperature
probe is out of range. The machine will
continue to run cycles.
Low Water In
Booster (Time
Out Within Any
Cycle)
FILL ERROR
Service Required
(Service Phone Number)
Error displayed if the unit times out
before the unit is completely lled. The
machine will not operate and will only
allow power down.
Drain Error
DRAIN ERROR
Service Required
(Service Phone Number)
Error displayed if the water level in the
unit will not come up. The machine will
not operate and will only allow power
down.
Sump Level
Error
SUMP LEVEL SENSOR
Service Required
(Service Phone Number)
OPEN or SHORT
Error displayed if sump pressure switch
is out of range. The machine will not
operate and will only allow power down.
Booster Level
Error
BOOSTER LEVEL SENSOR
Service Required
(Service Phone Number)
OPEN or SHORT
Error displayed if booster pressure switch
is out of range. The machine will not
operate and will only allow power down.