ELECTRICAL CONNECTION
Electrical and grounding connections must comply with the applicable portions of
the National Electrical Code and/or other local electrical codes.
Disconnect the electrical power to the machine and follow lockout/tagout procedures.
ELECTRICAL DATA
Complied in accordance with the National Electrical Code NFPA-70, latest addition.
For supply connections, use copper wire only rated at 90°C minimum.
*The (3W) systems require three power wires that include a current carrying neutral. An additional
fourth wire must be provided for machine ground.
Refer to the data plate on the door handle of the machine and the electrical label on the back side of
the lower front panel for proper selection.
ledoM esahP/ztreH/stloV
tiucriCylppuSmuminiM
yticapmArotcudnoC
evitcetorPmumixaM
yticapmAeciveD
LXeC
LXePR
1/06/021
LXeH
LXeR
20 20
40 40
30 30
40 40
208-240/60/1
208-240/60/3
120/208-240(3W)/60/1*
220-240/50/1